![](https://static.wixstatic.com/media/ffce19_7e1b0e620b6d40b8846a7c6174cf36ce~mv2_d_3980_2239_s_2.jpg/v1/fill/w_88,h_50,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/ffce19_7e1b0e620b6d40b8846a7c6174cf36ce~mv2_d_3980_2239_s_2.jpg)
TECHNOLOGIES
![RD01_2-miniblue-compressor.png](https://static.wixstatic.com/media/ffce19_b9eb5b9ba4ce402eb1f0a0414aa89946~mv2.png/v1/fill/w_447,h_381,al_c,q_95,enc_auto/RD01_2-miniblue-compressor.png)
![RD01_2-miniblue-compressor.png](https://static.wixstatic.com/media/ffce19_b9eb5b9ba4ce402eb1f0a0414aa89946~mv2.png/v1/crop/x_184,y_162,w_215,h_217/fill/w_278,h_279,al_c,lg_1,q_95,enc_auto/RD01_2-miniblue-compressor.png)
ROTARY DIAPHRAGM TECHNOLOGY
Rotary diaphragm pumps use unique Charles Austen patented technology. The flow of liquid is initiated by an eccentrically mounted bearing on a drive shaft revolved within a flexible diaphragm. As the shaft rotates, the bearing flexes the diaphragm, squeezing liquid through the pump. These pumps have outstanding self-priming characteristics and are of a valve-less, seal-less design making it suitable for condensate removal.
![Asset-5-compressor (1).jpg](https://static.wixstatic.com/media/ffce19_0d82530f4f474974839405ab969d471d~mv2.jpg/v1/fill/w_935,h_72,al_c,q_90,enc_auto/Asset-5-compressor%20(1).jpg)
GYROK™ PUMPING PRINCIPLE
With similar capabilities The patented GyRok pumping principle employs a elastomeric conical diaphragm displaced by a number of legs positioned annularly around a nutating drive element. The legs provide control of almost the entire diaphragm, giving outstanding self-priming characteristics. The pump is whisper quiet, able to tolerate extended periods of dry-running and can be mounted in any orientation in a number of locations, both above and below false ceilings.
![MICRO1-compressor.jpg](https://static.wixstatic.com/media/ffce19_91d0808ad79a475ca6e2bd81edb9a668~mv2.jpg/v1/fill/w_74,h_39,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/MICRO1-compressor.jpg)
![Asset-6-compressor (1).jpg](https://static.wixstatic.com/media/ffce19_10886331f1c24b3db9b6a425909a85cf~mv2.jpg/v1/fill/w_74,h_39,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/Asset-6-compressor%20(1).jpg)
![Asset-7-compressor.jpg](https://static.wixstatic.com/media/ffce19_a9160911214e45859ca5d4853218d606~mv2.jpg/v1/fill/w_74,h_39,al_c,q_80,usm_0.66_1.00_0.01,blur_2,enc_auto/Asset-7-compressor.jpg)
PUMP ALARM SYSTEMS
FSA
Fail safe alarm, a volt free relay designed to switch the AC unit off, but leaves the pump running continuously when the condensate reaches a critical point in the reservoir.
HLA
High Level Audio is an integral audio and visual alarm. When the condensate is at a critical point with-in the reservoir, the diagnostic light in the pump will switch from green and will start to flash red with a 2 beep warning every minute. The pump will continue to operate while in alarm mode.